Related Experiment Video
Updated: Dec 5, 2025

A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
Endothelial Dysfunction-related Neurological Bleeds with Continuous Flow-Left Ventricular Assist Devices Measured by
Areeba Ali1, Cesar Uribe1, Raquel Araujo-Gutierrez1
1From the Methodist DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, Texas.
Abstract:
Endothelial dysfunction has been demonstrated in patients with Continuous Flow-Left Ventricular Assist Devices (CF-LVADs) but association with adverse events has not been shown. We used a noninvasive, operator-independent device called VENDYS® to assess vasodilatory function based on digital thermal measurements postrelease of a brachial artery occlusion in ambulatory patients with CF-LVAD (n = 56). Aortic valve opening and pulse perception were also documented before the test. Median duration of CF-LVAD support was 438 days. The VENDYS® test generates a vascular reactivity index (VRI). Outcomes for the CF-LVAD patients were compared between VRI < 1 and VRI ≥ 1. The bleeding events were driven primarily by a difference in neurologic bleeds. Multivariate analysis showed that VRI < 1 correlated with future bleeding events (HR: 5.56; P = 0.01). The C-statistic with the VRI dichotomized as above was 0.82. There was a trend toward a worse survival in patients with poor endothelial function. Endothelial vasodilatory dysfunction measured by a simple test utilizing digital thermal monitoring can predict adverse bleeding events in patients with CF-LVADs.