Related Experiment Video
Updated: Dec 5, 2025

The Preparation of Electrohydrodynamic Bridges from Polar Dielectric Liquids
Published on: September 30, 2014
Breakup of an electrified viscoelastic liquid bridge
Manuel Rubio1, Emilio J Vega1, Miguel A Herrada2
1Departamento de Ingeniería Mecánica, Energética y de los Materiales, Instituto de Computación Científica Avanzada (ICCAEx), Universidad de Extremadura, Avenida de Elvas s/n, E-06006 Badajoz, Spain.
Abstract:
We study both numerically and experimentally the breakup of a viscoelastic liquid bridge formed between two parallel electrodes. The polymer solutions and applied voltages are those commonly used in electrospinning and near-field electrospinning. We solve the leaky-dielectric finitely extensible nonlinear elastic-Peterlin (FENE-P) model to describe the dynamical response of the liquid bridge under isothermal conditions. The results show that the surface charge screens the inner electric field perpendicular to the free surface over the entire dynamical process. The liquid bridge deformation produces a normal electric field on the outer side of the free surface that is commensurate with the axial one. The surface conduction does not significantly affect the current intensity in the time interval analyzed in the experiments. The force due to the shear electric stress becomes comparable to both the viscoelastic and surface tension forces in the last stage of the filament. However, it does not alter the elastocapillary balance in the filament. As a consequence, the extensional relaxation times measured from the filament exponential thinning approximately coincides with the stress relaxation time prescribed in the FENE-P model. The above results allow us to interpret correctly the experiments. In the experiments, we measure the filament electrical conductivity and extensional relaxation time for polyethylene oxide (PEO) dissolved in deionized water and in a mixture of water and glycerine. We compare the filament electrical conductivity with the value measured in hydrostatic conditions for the same estimated temperature. Good agreement was found for PEO dissolved in water + glycerine, which indicates that the change in the filament microscopic structure due to the presence of stretched polymeric chains does not significantly alter the ion mobility in the stretching direction. Significant deviations are found for PEO dissolved in deionized water. These deviations may be attributed to the heat transferred to the ambient, which is neglected in the calculation of the filament temperature. We measure the extensional relaxation time from the images acquired during the filament thinning. The relaxation times obtained in the first stage of the exponential thinning hardly depend on the applied voltage. Little but measurable influence of the applied voltage is found in the last phase of the filament thinning.
More Related Videos
11:03An Analog Macroscopic Technique for Studying Molecular Hydrodynamic Processes in Dense Gases and Liquids
Published on: December 4, 2017
08:42Challenges in Rheological Characterization of Highly Concentrated Suspensions — A Case Study for Screen-printing Silver Pastes
Published on: April 10, 2017
Related Concept Videos
Electrostatic Boundary Conditions in Dielectrics
Consider a case where both the mediums across a boundary are two different dielectric materials. Recall that the electric field and electric displacement are proportional and related through the material's permittivity....
Theories of Dissolution: The Danckwerts' Model and Interfacial Barrier Model
Electrostatic Boundary Conditions
The surface integral of an electric field is given by Gauss's law in integral form and is related to...
Design Example: Strain Gauge Bridge or Wheatstone Bridge
Elastic Strain Energy for Shearing Stresses
Viscosity of Fluid