A sandwich temperature control membrane inlet mass spectrometer for dissolved gases and volatile organic compounds in
Yongqiang Cheng1, Maoke Liu2, Bin Zhao2
1Institute of Eco-Environmental Forensics, Qingdao Institute of Humanities and Social Sciences, Shandong University, China.
Abstract:
A sandwich temperature control membrane inlet system based on a miniature mass spectrometer is presented that demonstrates improved analytical performance for the measurement of dissolved gases and volatile organic compounds (VOCs) in aqueous solution. Aqueous solution is directly brought to the monolayer flat membrane interface at a constant flow rate. A heating resistor and a thermocouple are fixed on the side of the membrane and aqueous solution respectively. This new strategy allows for a temperature compensation method, affording an improvement of sensitivity and a reduction of response time compared with the conventional heating solution temperature control strategy. Furthermore, a static heating mode is applied to effectively remove the memory effect. Automatic sampling and measurement are achieved by using the membrane inlet system with silicone sheeting of 50 μm thickness. The vacuum is below 3 × 10-5 Torr, which can make the instrument work normally. A good linear response is observed for benzene in the range of 0.1 ppm-10 ppm and the detection limit is 50 ppb. The analytical capacity of this system is demonstrated by the on-line analysis of VOCs in aqueous solution, in which the dominant ions are detected rapidly. The results indicate that the sandwich temperature control membrane inlet mass spectrometer (STC-MIMS) has a potential application for on-line analyzing organic pollution in aquatic environments.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometers
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Gas Chromatography: Types of Detectors-II
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...