Sodium dodecyl sulfate-multi-walled carbon nanotubes-coated-membrane solid phase extraction of glucocorticoids in
Shalene Xue Lin Goh1, Esther Xue Yi Goh2, Hian Kee Lee1
1Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore, 117543, Singapore; NUS Environmental Research Institute, National University of Singapore, T-Lab Building #02-01, 5A Engineering Drive 1, Singapore, 117411, Singapore.
Abstract:
A membrane-based solid phase extraction (SPE)-ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the determination of nine glucocorticoids in water. This new hybrid SPE approach involved the deposition of sodium dodecyl sulfate (SDS)-multi-walled carbon nanotubes (MWCNTs) on a piece of polypropylene membrane that served as the extraction device. Hitherto, such a sample preparation procedure has not been applied to the analysis of water contaminants before. The use of the surfactant helped to disperse the MWCNTs effectively so that they were coated uniformly onto the polypropylene membrane. This increased the overall extraction efficiency of the procedure. Characterisation of the SDS-MWCNTs material was performed using transmission electron microscopy and scanning electron microscopy. The membrane device did not require a pre-conditioning step. The most favourable extraction parameters such as type of surfactant, percentage of surfactant, type of desorption solvent, stirring rate, desorption time, extraction time, temperature, salting-out effect, pH and diameter of MWCNTs were obtained. The method showed linearity ranges from 0.2 to 100 ng mL-1 for hydrocortisone, dexamethasone, cortisone acetate and beclomethasone dipropionate, and 0.5-100 ng mL-1 for the rest of the analytes. Limits of detection ranging from 0.019 to 0.098 ng mL-1, and limits of quantification ranging from 0.065 to 0.326 ng mL-1, were obtained for the analytes. The intra-day repeatability was between 1.77 and 3.56% while the inter-day reproducibility was between 2.69 and 9.53%, respectively. The method was used to analyse glucocorticoids as contaminants in the canal water samples.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
10:09A Straightforward Method for Glucosinolate Extraction and Analysis with High-pressure Liquid Chromatography HPLC
Published on: March 15, 2017
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
