Background:
The aim of this study was to evaluate via finite element analysis (FEA) the biomechanical behavior of conventional small-fragment screws reinforced by a patient-specific plate in type p condylar head.
Methods:
A finite element model of the mandible was created using Mimics 12.1 software. A type p condylar head fracture was simulated in the right condyle, and the left condyle was used as a control. Two patterns of fixation were investigated: conventional two-screw fixation and the same fixation system reinforced with a small, patient-specific plate. Surface models were imported into the software Ansys 5.7for further volume mesh generation.
Results:
The highest stress gradients were observed in the cortical layer of the lateral fragment, located near the screw. The conventional fixation method resulted in equivalent stresses 2 to 10 times greater than the reinforced method. Rigidity of fixation in the reinforced method increased up to 1.25-3 times compared to the conventional two-screw technique.
Conclusion:
This study's findings suggest significant benefits in unfavorable biomechanical conditions from reinforcement of the standard two-screw fixation of condylar head fractures with a small, patient-specific plate acting as a washer.