Related Experiment Video
Updated: Dec 5, 2025

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Does Size Matter for Cephalomedullary Nails in Geriatric Intertrochanteric Fractures?
Dustin B Rinehart1, David E O'Neill, Jennifer W Liu
1Department of Orthopaedic Surgery, UT Southwestern Medical Center, Dallas, TX.
Objectives:
To evaluate the need for reoperation of geriatric intertrochanteric hip fractures treated with 10-mm cephalomedullary nails versus those treated with nails larger than 10 mm.
Design:
Retrospective review at a single institution.
Setting:
Level I trauma center.
Patients/Participants:
All patients age 60 and over treated with cephalomedullary fixation for an intertrochanteric femur fracture at a single institution.
Intervention:
Cephalomedullary fixation with variable nail diameters.
Main Outcome Measurements:
Reoperation rates of geriatric intertrochanteric fractures treated with a size 10-mm diameter cephalomedullary nail compared with patients treated with nails larger than 10 mm.
Results:
There were no significant differences in reoperation rates when the 10-mm cohort was compared with an aggregate cohort of all nails larger than 10 mm (P = 0.99). This result was true for both all-cause reoperation and noninfectious reoperation. There was no difference between cohorts in regards to age, gender, or fracture pattern.
Conclusions:
A 10-mm cephalomedullary nail can be used in lieu of a larger diameter fixation in patients age 60 and older with intertrochanteric femur fractures while still maintaining a comparable rate of reoperation.
Level Of Evidence:
Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016