Unsaturated Zone Flow Processes and Aquifer Response Time in the Chalk Aquifer, Brighton, South East England

Peshawa Al-Jaf, Martin Smith1, Friederike Gunzel2

  • 1School of Environment and Technology, University of Brighton, Brighton, Lewes Road, BN2 4GJ, UK.

Ground Water
|October 21, 2020
PubMed

Related Concept Videos

Uniform Depth Channel Flow01:27

Uniform Depth Channel Flow

Uniform depth channel flow keeps fluid depth consistent along channels such as irrigation canals. In natural channels, such as rivers, approximate uniform flow is often assumed. This condition occurs when the channel’s bottom slope matches the energy slope, balancing potential energy lost from gravity with head loss due to shear stress. This balance prevents depth changes along the channel length, resulting in a steady, uniform flow.Uniform flow in open channels with a constant cross-section...
412
Testing Water Quality01:14

Testing Water Quality

When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
274
Rapidly Varying Flow01:24

Rapidly Varying Flow

Rapidly varying flow (RVF) in open channels is characterized by abrupt changes in flow depth over a short distance, with the rate of depth change relative to distance often approaching unity. These flows are inherently complex due to their transient and multi-dimensional nature, making exact analysis difficult. However, approximate solutions using simplified models provide valuable insights into their behavior.Key Features of Rapidly Varying FlowRVF is commonly observed in scenarios involving...
303
Uniform Depth Channel Flow: Problem Solving01:18

Uniform Depth Channel Flow: Problem Solving

To calculate the flow rate for a trapezoidal channel, first, identify the bottom width, side slope, and flow depth of the channel. The cross-sectional area (A) corresponding to the depth of flow (y), channel bottom width (B), and side slope (θ) is determined by:Next, calculate the wetted perimeter, which includes the bottom width and the sloped side lengths in contact with the water. Using the values of the cross-sectional area and the wetted perimeter, determine the hydraulic radius by...
327
Transition Zone01:28

Transition Zone

The transition zone in concrete is a critical area where aggregate meets cement paste, marked by a distinct porosity and weakness compared to the surrounding material. The adhesion around the aggregates is primarily due to Van Der Waals forces. The voids within this zone influence its robustness; initially, it is less durable than the surrounding bulk mortar due to larger voids. Initially, when concrete is compacted, a higher water-cement ratio near the aggregates leads to the formation of...
251
Energy Considerations in Open Channel Flow01:27

Energy Considerations in Open Channel Flow

Open channel flow, where a fluid flows with a free surface exposed to the atmosphere, is primarily governed by gravitational and surface effects, distinguishing it from closed conduit or pipe flow. In open channels such as rivers, canals, and artificial channels, energy analysis provides valuable insights into flow behavior and the relationship between depth, velocity, and slope.Specific Energy and Flow DepthIn open channel flow, the specific energy, E, combines the gravitational potential...
433