APPLICABILITY OF VENTILATION SYSTEMS FOR REDUCING THE INDOOR RADON CONCENTRATION
Martin Jiránek1, Veronika Kačmaříková1
1Czech Technical University, Faculty of Civil Engineering, Thákurova 7, 166 29 Praha 6, Czech Republic.
Abstract:
An analysis is presented of the ability of balanced mechanical ventilation systems to reduce the radon concentration in residential buildings efficiently. The analysis takes into account the following parameters: radon supply rate into the building, ventilation intensity, required indoor radon concentration and energy consumption. It is shown that the applicability of ventilation systems is limited mainly by energy consumption. Ventilation systems can be considered energetically acceptable if the ventilation intensity does not exceed 0.6 h-1, i.e. radon supply rate should not exceed 60 Bq/m3h for a required indoor radon concentration of 100 Bq/m3. Energy consumption can be significantly reduced by operating the ventilation system in a cyclic mode. Simulating the behavior of ventilation systems in time has been found as a useful tool for their design. In order to express by one parameter energy consumption and radon reduction, a completely new quantity-the 'radon-related energy need' has been proposed.
More Related Videos
08:23Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry
Published on: June 14, 2018
08:26Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiation: Applications
The average...
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...