Pull-out forces of headless compression screws in variations of synthetic bone models imitating different types of
Jochen Erhart1, Ewald Unger2, Inga Trulson3
1Department of Trauma Surgery, General Hospital of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria. jochen.erhart@bbeisen.at.
Abstract:
Screw osteosynthesis using headless compression screws has become the accepted gold standard for the surgical treatment of scaphoid fractures. Optimal screw specifications remain controversially discussed. We aimed to investigate the influence of bone model composition on screw stability tests using headless compression screws in different scaphoid fracture models. We conducted pull-out tests using Acutrak2®mini, HCS®, HKS®, HBS®, Herbert/Whipple® and Twinfix® screws. To imitate cortical and cancellous bone, two-layer polyurethane (PU) models with two distinct densities were produced. The cylinders were cut at different positions to replicate fracture localisations at increasing distances. The maximum pull-out force required to achieve up to 1 mm of pull-out distance (Nto 1 mm) was measured. Acutrak2®mini and HCS® followed by Twinfix® showed the greatest average pull-out forces. Nto 1 mm was, on average, greater in the cortico-cancellous model than in the cancellous cylinder with the Acutrak2®mini and the Herbert/Whipple® screws, while it was the least with the HBS® and the Twinfix® screws; there were also differences between the HCS® and HKS®. There were no differences between the different fracture simulations in the synthesis strength using either the HKS® or HBS®. The pull-out forces of the HCS® and Twinfix® remained high also in simulations with the smaller screw base fragments. Varying imitations of cancellous and cortico-cancellous bone and fracture localisation reveal important information about the ex vivo strength of screw syntheses. The grip of the cortical structure should be used with the screws that fit more firmly in cortico-cancellous bone.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Related Concept Videos
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...