The strengths and weaknesses of viscoelastic testing compared to traditional coagulation testing

Tobias Cohen1,2, Thorsten Haas3, Melissa M Cushing1,2

  • 1Department of Pathology and Laboratory Medicine, Weill Cornell Medicine, New York, New York, USA.

Transfusion
|October 22, 2020
PubMed

Optimized acute bleeding management requires timely and reliable laboratory testing to detect and diagnose coagulopathies and guide transfusion therapy. Conventional coagulation tests (CCT) are inexpensive with minimal labor requirements, but CCTs may have delayed turnaround times. In addition, abnormal CCT values may not reflect in vivo coagulopathies that require treatment and may lead to overtransfusion. The use of viscoelastic testing (VET) has been rapidly expanding and is recommended by several recent bleeding guidelines. This review is intended to compare CCT to VET, review the strengths and weaknesses of both approaches, and evaluate and summarize the clinical studies that compared CCT-based and VET-based transfusion algorithms. Most studies of CCT vs VET transfusion algorithms favor the use of VET in the management of massively bleeding patients due to reductions in blood product utilization, bleeding, costs, and lengths of stay.

Related Concept Videos

Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
668
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
832
Non-destructive Tests for Concrete Strength01:12

Non-destructive Tests for Concrete Strength

The rebound hammer test, also known as the Schmidt hammer test, is a non-destructive technique for evaluating the hardness of concrete and, indirectly, the strength of concrete. It operates on the principle that the rebound of a spring-driven mass from a concrete surface correlates to the surface's hardness. The device comprises a mass within a tubular housing, a spring mechanism, and a plunger that strikes the concrete. Upon release, the energy imparted to the mass by the spring causes it...
328