Related Experiment Video
Updated: Dec 4, 2025

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
Effect of contrast dose on diagnostic performance in DCE-MR breast imaging
Thuy-My Thi Le1, Elizabeth S McDonald1, Gamaliel Isaac1
1Department of Radiology, University of Pennsylvania School of Medicine, Philadelphia, PA, USA.
Objective:
To assess the diagnostic performance of breast magnetic resonance (MR) imaging as a function of gadolinium contrast dose using a retrospective reader study.
Material And Methods:
IRB approval was obtained prior to the start of this study and was HIPAA compliant. One-hundred and fifty MR breast examinations were included that were acquired between January 2001 and December 2006. Seventy-five patients received contrast doses (gadopentetate dimeglumine) by weight of 0.10 mmol/kg and 75 patients were imaged using fixed volumes of 20 ml. The images were assessed by two radiologists with performance calculated for each reader as well as a combined assessment. Dose response was measured by comparing performance between cases binned by dose: <=0.10; >0.10; and >0.13 mmol/kg. Statistical significance was calculated using a one-sided Z-test for differences in proportions with interobserver agreement calculated using Cohen's kappa statistics.
Results:
In the combined reader assessment with equivocal lesions classified as negative, sensitivity rose from 66% (19/29) to 92% (24/26, P < 0.01) and 95% (18/19, P < 0.01) with the specificity also increasing from 65% (32/49) to 87% (40/46, P < 0.01) and 86% (32/37, P = 0.01) corresponding to doses <=0.10, >0.10, >0.13 mmol/kg. With equivocal lesions classified as positive, sensitivity rose from 79% (23/29) to 92% (24/26, P < 0.10) and 95% (18/19, P < 0.10) Specificity also increased from 53% (26/49) to 72% (33/46, P < 0.05) and 70% (26/37, P = 0.05) with increasing dose. Interobserver agreement also improved at the higher doses.
More Related Videos
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
11:27Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography