Related Experiment Video
Updated: Dec 4, 2025

Installation Method to Enhance Quality Control for Fiber Reinforced Polymer Spike Anchors
Published on: April 10, 2018
Average Force of Deployment and Maximum Arrest Force of Energy Absorbers Lanyards
Elena Ángela Carrión1,2, Pedro Ignacio Saez1, Juan Carlos Pomares3
1Building & Urban Development Department, University of Alicante, 03690 Alicante, Spain.
Abstract:
Energy-absorbing lanyards (EAL) are part of fall arrest systems (FAS), their main mission is to dissipate the energy generated during the fall, ensuring that the arresting force does not cause injury to the user. For the design of FAS as set out in the American standard Z359.6 and the Canadian Z259.16 it is essential to know the deployment force or average arrest force (Fa). Fa is necessary to estimate the elongation that the absorber will suffer during the fall and therefore essential data to calculate the clearance distance. There is a lack of useful experimental data for the design of this personal protective equipment (PPE). This work provides empirical data required for the design of FAS with EAL in accordance with EN 355. This paper covers different types of EAL that are marketed internationally; different empirical data, average and maximum forces, required for improving safety design are researched. Six manufacturers, 10 models, and 2 samples of each model were selected, with total of 20 tests being performed. Dynamic performance tests were carried out, the free fall of a person was simulated using a 100 kg steel ballast from the maximum height allowed by the equipment, obtaining the maximum arrest force (Fm), average deployment force (Fa), and, by calculating the balance of forces, the maximum and average acceleration suffered by the ballast during its arrest. In light of the results, relevant conclusions for user safety are obtained. It is feasible to raise the safety requirements established by the different standards. The Fm can be established below 6 kN in the EAL, and the Fa can be estimated at 87.5% of the Fm. The categorization of the force-time curve in fall arrest with EAL has been obtained. Two EAL purchased on the market exceed the Fm permitted, therefore it is recommended to increase the quality controls of EAL.
More Related Videos
Related Concept Videos
Cable Subjected to a Distributed Load
Cable Subjected to Concentrated Loads
Impact Loading
In cases of elastic deformation,...
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
Cable: Problem Solving
Applications of Stress
The...