Formulation and Acoustic Modulation of Optically Vaporized Perfluorocarbon Nanodroplets
Published on: July 16, 2021
Transient acoustic vaporization signatures unique to low boiling point phase change contrast agents enable
R M DeRuiter1, E N Markley1, J D Rojas1
1Joint Department of Biomedical Engineering, University of North Carolina-Chapel Hill and North Carolina State University, 116 Manning Drive, 9018 Mary Ellen Jones Building, CB7575, Chapel Hill, North Carolina 27599, USA.
Abstract:
The unique activation signal of phase-change contrast agents (PCCAs or droplets) can be separated from the tissue signal and localized to generate super-resolution (SR) ultrasound (US) images. Lipid-shelled, perfluorocarbon PCCAs can be stochastically vaporized (activated) by a plane wave US transmission thereby enabling them to be used as separable targets for ultrasound localization microscopy. The unique signature of droplet vaporization imaging and the transient inherent nature of this signature increases signal contrast and therefore localization confidence, while the poor resolution of the low-frequency vaporization signal is overcome by the super-resolution result. Furthermore, our proposed PCCA SR technique does not require the use of user-dependent and flow-dependent spatio-temporal filtering via singular-value decomposition. Rather, matched filters selected by Fourier-domain analysis are able to identify and localize PCCA activations. Droplet SR was demonstrated in a crossed-microtube water phantom by localizing the activation signals of octafluoropropane nanodroplets (OFP, C3F8, -37 °C boiling point) to resolve 100 µm diameter fluorinated ethylene propylene tubes, which are ordinarily 35% smaller than the native diffraction-limited resolution of the imaging system utilized.
More Related Videos
Related Concept Videos
Phase Transitions: Vaporization and Condensation
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Super-resolution Fluorescence Microscopy