Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
Isolated left atrial cryoablation of atrial fibrillation in conventional mitral valve surgery
Giuseppe Gatti1, Ilaria Fiorica1, Luca Dell'Angela2
1Cardio-Thoracic & Vascular Department, Trieste University Hospital, Trieste, Italy.
Background:
Recent trends of surgery for atrial fibrillation (AF) are towards more safe and effective energy sources, as well as to simplified sets of atrial lesions.
Methods:
One hundred eighteen (mean age, 67.4 ± 9.2 years) selected patients with paroxysmal/persistent AF and mitral valve (MV) disease underwent cryoablation of AF combined with conventional (not via mini-thoracotomy) MV surgery; the lesion set was limited to only the left atrium. Multivariable analyses identified predictors of cardiac rhythm at hospital discharge and follow-up.
Results:
There were 7 (5.9%) hospital deaths; 33 (28%) patients were discharged on AF. Higher values of preoperative left atrial volume index (odds ratio [OR] = 1.07, 95% confidence interval [95%CI]: 1.01-1.13) and mixed etiology of MV disease (OR = 4.19, 95%CI: 1.23-14.2) were predictors of hospital discharge on AF. Seventy-four (66.7%) patients were on stable sinus rhythm at follow-up (median period, 6.6 years); the 1, 5, and 10-year nonparametric estimates of adjusted freedom from AF were 98.1%, 89.2% and 45.6%, respectively. Higher values of preoperative systolic pulmonary artery pressure (hazard ratio [HR] = HR = 1.04, 95%CI: 1.01-1.08) and AF at hospital discharge (HR = 4.14, 95%CI: 1.50-11.4) were predictors of AF at follow-up.
Conclusions:
During conventional MV surgery, a cryo-lesion set limited to only the left atrium may give good, immediate and long-term results. Left atrial dilation and mixed etiology of MV disease were predictors of hospital discharge on AF. Preoperative pulmonary hypertension and AF at discharge combined with an increased risk of AF at follow-up.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
11:03Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
Related Concept Videos
Mitral Stenosis III: Medical Management
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Stenosis I: Introduction
Mitral Regurgitation III: Medical Management