Related Experiment Video
Updated: Dec 3, 2025

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
Published on: February 9, 2022
Optimizing Intersession Reliability of Heart Rate Variability-The Effects of Artifact Correction and Breathing Type
Angela S Gisselman1, Maria D'Amico2,3, James M Smoliga4
1Centre for Health, Activity and Rehabilitation Research, School of Physiotherapy, University of Otago, Dunedin, New Zealand.
Abstract:
Gisselman, AS, D'Amico, M, and Smoliga, JM. Optimizing intersession reliability of heart rate variability-the effects of artifact correction and breathing type. J Strength Cond Res 34(11): 3199-3207, 2020-This study aimed to comprehensively investigate the reliability of multiple heart rate variability (HRV) parameters and to explore the influence of artifact removal and breathing condition on HRV reliability. Resting HRV was collected using Polar Team monitors on 41 participants (age: 19.9 ± 1.2 years; 28 females and 13 males) during 2 separate days. Within each session, participants performed 10 minutes each of spontaneous and controlled breathing (randomized order). Kubios HRV analysis software was used to analyze 180-second data epochs using "low" or "strong" artifact removal. Relative reliability was assessed using intraclass correlation coefficient (ICC2,1), and absolute reliability was quantified using mean-normalized SEM%. Time-domain and nonlinear parameters produced poor to good intersession agreement (ICC = 0.34-0.68; SEM% = 11.0-39.0) with "low" artifact removal, regardless of breathing condition. Frequency-domain parameters demonstrated fair intersession agreement during controlled breathing (ICC = 0.40-0.45; SEM% = 26.0-70.0) but poor agreement during spontaneous breathing (ICC = 0.07-0.13; SEM% = 32.0-81.0). Minimal differences in ICCs were observed between "low" and "strong" artifact removal. Thus, this study provides 3 practical applications: (a) HRV monitoring is most reliable when using time-domain and nonlinear parameters, regardless of breathing or filtering condition, but no single parameter is especially reliable. The large variation and poor intersession reliability of frequency indices during spontaneous breathing are improved by controlling breathing rate; (b) "Low" artifact removal seems superior to more aggressive artifact removal; and (c) intersession differences in HRV measurements <30% may be indicative of normal daily variation rather than true physiologic changes.
More Related Videos
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...