Related Experiment Video
Updated: Dec 3, 2025

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
No difference in gait pattern between a short collum femoris-preserving and a conventional stem: 44 randomised total
Roland Zügner1, Roy Tranberg1, Johan Kärrholm1
1Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden.
Background:
The uncemented collum femoris-preserving (CFP) stem offers preservation of the femoral neck and a more conservative soft tissue resection, which may facilitate a more normal walking pattern. We used gait analysis to evaluate if patients operated with a CFP stem showed more favourable hip kinematics and kinetics when compared with a group of patients operated with a conventional uncemented stem.
Methods:
44 patients randomised to receive either a CFP or a Corail stem were studied and were operated using a direct lateral incision. Gait analysis was performed 2 years after the operation with a 12-camera motion capture system and 2 force plates. Hip kinematics and kinetics were analysed and 66 subjects served as controls.
Results:
None of the variables: speed, stride, cadence and stance showed any statistical significant difference between the 2 study groups. Neither did the hip kinematics and kinetics. Compared to controls, patients operated with the CFP stem showed an increased stance (62.5% vs. 61.1%, p < 0.006) and decreased hip abduction (-2.1° vs. -6.5°). Patients operated with the Corail stem showed decreased speed (1.18 vs. 1.23 m/second), and stride length (1.26 vs. 1.33 m), decreased hip extension (-7.5° vs. -12.8°) and range of hip flexion/extension (38° vs. 40.9°), as well as their hip adduction that was increased (6.3° vs. 4°), whereas their hip abduction was reduced (-2.8° vs. -6.5°), (p < 0.004) compared to the controls.
Conclusions:
Use of a CFP stem did not significantly influence any of the gait parameters studied when compared to a standard stem, but still both stems studied were associated with gait deviations when compared to controls. Whether these differences could be attributed to the stem used, the underlying hip disease, or both is still unknown.
More Related Videos
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
07:44Evaluation of Patients' Posture and Gait Profile After Lumbar Fusion Surgery by Video Rasterstereography and Treadmill Gait Analysis
Published on: March 23, 2019