Related Experiment Video
Updated: Dec 3, 2025

Author Spotlight: Assessing the Reliability of Doppler Ultrasound in Measuring Leg Blood Flow
Published on: December 15, 2023
Fluid responsiveness to passive leg raising in patients with and without coronary artery disease: A prospective
Varun Suresh1, Manikandan Sethuraman2, Jayakumar Karunakaran3
1Division of Neuro-Anaesthesia, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala, India.
Introduction:
Hemodynamic stability and fluid responsiveness (FR) assume importance in perioperative management of patients undergoing major surgery. Passive leg raising (PLR) is validated in assessing FR in intensive care unit patients. Very few studies have examined FR to PLR in intraoperative scenario. We prospectively studied FR to PLR using transesophageal echocardiography (TEE), in patients with no coronary artery disease (CAD) undergoing major neurosurgery and those with CAD undergoing coronary artery bypass grafting (CABG).
Methods:
We enrolled 29 adult consenting patients undergoing major neurosurgery with TEE monitoring and 25 patients undergoing CABG. After induction of anesthesia, baseline hemodynamic parameters were obtained which was followed by PLR using automated adjustment of the operating table. Clinical and TEE-derived hemodynamic parameters were recorded at 1 and 10 min after PLR following which patients were returned to supine position.
Results:
A total of 162 TEE and clinical examinations were done across baseline, 1 and 10 min after PLR; and paired comparison was done at data intervals of baseline versus 1 min PLR, baseline versus 10 min PLR, and 1 min versus 10 min PLR. There was no significant change in hemodynamic variables at any of the paired comparison intervals in patients undergoing neurosurgery. CABG cases had significant hemodynamic improvement 1 min after PLR, partially sustained at 10 min.
Conclusion:
Patients undergoing CABG had significant hemodynamic response to PLR, whereas non-CAD patients undergoing neurosurgery did not. A blood pressure-left ventricular end-diastolic volume combination represented strong correlation in response prediction (Pearson's coefficient 0.641; P < 0.01).
More Related Videos
Related Concept Videos
Assessing Blood pressure in the Leg
Preparation:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Artery Disease IV: Nursing Management
Peripheral Artery Disease V: Postoperative Nursing Management
Pre-Procedural Guidelines for Assessing Blood Pressure