Related Experiment Video
Updated: Dec 3, 2025

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Improved Estimation of Glycated Hemoglobin from Continuous Glucose Monitoring and Past Glycated Hemoglobin Data
Jędrzej Chrzanowski1, Arkadiusz Michalak1,2, Aleksandra Łosiewicz2
1Department of Biostatistics and Translational Medicine, Diabetology, Endocrinology and Nephrology, Medical University of Lodz, Lodz, Poland.
Abstract:
Accurate estimation of glycated hemoglobin (HbA1c) from continuous glucose monitoring (CGM) remains challenging in clinic. We propose two statistical models and validate them in real-life conditions against the current standard, glucose management indicator (GMI). Modeling utilized routinely collected data from patients with type 1 diabetes from central Poland (eligibility criteria: age >1 year, diabetes duration >3 months, and CGM use between 01/01/2015 and 12/31/2019). CGM records were extracted from dedicated Medtronic/Abbott databases and cross-referenced with HbA1c values; 28-day periods preceding HbA1c measurement with >75% of the sensor-active time were analyzed. We developed a mixed linear regression, including glycemic variability indices and patient's ID (glucose variability-based patient specific model, GV-PS) intended for closed-group use and linear regression using patient-specific error of GMI (proportional error-based patient agnostic model, PE-PA) for general use. Models were validated with either new HbA1cs from closed-group patients or separate patient-HbA1c pool. External validation was performed with data from clinical trials. Performance metrics included bias, its 95% confidence interval (95% CI), coefficient of determination (R2), and root mean square error (RMSE). We included 723 HbA1c-CGM pairs from 174 patients (mean age 9.9 ± 4.4 years and diabetes duration 3.7 ± 3.6 years). GMI yielded R2 = 0.58, with different bias between Medtronic and Abbott devices [0.120% vs. -0.152%, P < 0.0001], and overall 95% CI = -0.9% to +1%, RMSE = 0.47%. GV-PS successfully captured patient-specific variance (closed-group validation: R2 = 0.83, bias = 0.026%, 95% CI = -0.562% to 0.591%, RMSE = 0.31%). PE-PA performed similarly on new patients (R2 = 0.76, bias = -0.069%, 95% CI = -0.790% to 0.653%, RMSE = 0.37%). In external validation GMI, GV-PS, and PE-PA produced 73.8%, 87.5%, and 91.0% predictions within 0.5% (5.5 mmol/mol) from the true value. Constructed models performed better than GMI. PE-PA provided an accurate estimate of HbA1c with fast and straightforward implementation.