Related Experiment Video
Updated: Dec 3, 2025

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Rational design of mixtures for chromatographic peak tracking applications via multivariate selectivity
Daniel W Cook1, Kelson G Oram2, Sarah C Rutan1
1Department of Chemistry, Virginia Commonwealth University, Richmond, VA, 23284, USA.
Abstract:
Chromatographic characterization and parameterization studies targeting many solutes require the judicious choice of operating conditions to minimize analysis time without compromising the accuracy of the results. To minimize analysis time, solutes are often grouped into a small number of mixtures; however, this increases the risk of peak overlap. While multivariate curve resolution methods are often able to resolve analyte signals based on their spectral qualities, these methods require that the chromatographically overlapped compounds have dissimilar spectra. In this work, a strategy for grouping compounds into sample mixtures containing solutes with distinct spectral and, optionally, with distinct chromatographic properties, in order to ensure successful solute resolution either chromatographically or with curve resolution methods is proposed. We name this strategy rational design of mixtures (RDM). RDM utilizes multivariate selectivity as a metric for making decisions regarding group membership (i.e., whether to add a particular solute to a particular sample). A group of 97 solutes was used to demonstrate this strategy. Utilizing both estimated chromatographic properties and measured spectra to group these 97 analytes, only 12 groups were required to avoid a situation where two or more solutes in the same group could not be resolved either chromatographically (i.e., they have significantly different retention times) or spectrally (i.e., spectra are different enough to enable resolution by curve resolution methods). When only spectral properties were utilized (i.e., the chromatographic properties are unknown ahead of time) the number of groups required to avoid unresolvable overlaps increased to 20. The grouping strategy developed here will improve the time and instrument efficiency of studies that aim to obtain retention data for solutes as a function of operating conditions, whether for method development or determination of the chromatographic parameters of solutes of interest (e.g., k ).
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Analyte Adsorption and Distribution
Affinity Chromatography
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors