Detection and impact of hysteresis when evaluating a drug's QTc effect using concentration-QTc analysis
Georg Ferber1, Borje Darpo2, Christine Garnett3
1Statistik Georg Ferber GmbH, Cagliostrostrasse 14, 4125, Riehen, Switzerland. Statistik.Georg.Ferber@bluewin.ch.
Abstract:
Early-phase studies quantifying the QTc prolongation potential for a new drug often use linear concentration-QTc (C-QTc) models, assuming no delay between plasma concentrations and QTc changes. However, that assumption is not always correct. The term "hysteresis" has been utilized to describe a time lag present between a measurable concentration and a measurable effect. To detect and quantify hysteresis and its impact on study interpretation, studies with hysteresis of 0.25-4 h were simulated with different doses, half-lives, and sampling schedules in a crossover design. Hysteresis was quantified using a novel method termed exposure-normalized GRI (enGRI), a proposed modification of the Glomb-Ring Index (GRI), to account for delay and magnitude of QTc effects. With realistic sampling, the rate of false negative studies (FN) increased proportionally to the delay, even for delays shorter than 1 h. Using an enGRI threshold (γ) of 2 ms resulted in FN with undetected delay and FN without hysteresis at approximately the same rate. For γ = 2 ms, the specificity of enGRI was > 90% throughout the investigated scenarios. We therefore propose the incorporation of enGRI when interpreting results from C-QTc analysis with the intent of characterizing QTc effects.
More Related Videos
11:33All-electronic Nanosecond-resolved Scanning Tunneling Microscopy: Facilitating the Investigation of Single Dopant Charge Dynamics
Published on: January 19, 2018
10:07High-throughput Screening for Small-molecule Modulators of Inward Rectifier Potassium Channels
Published on: January 27, 2013
Related Concept Videos
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Time Course of Drug Effect
Therapeutic Drug Monitoring: Drug Analysis Methods
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Drug Dissolution: Requirements and Profile Comparison
Detection of Gross Error: The Q Test