Electrochemical non-enzymatic glucose sensors: recent progress and perspectives

Ming Wei1, Yanxia Qiao, Haitao Zhao

  • 1Key Laboratory of Magnetic Molecules and Magnetic Information Materials (Ministry of Education), School of Chemistry and Material Science, Shanxi Normal University, Linfen 041004, Shanxi, China. luwb@sxnu.edu.cn.

Chemical Communications (Cambridge, England)
|October 29, 2020
PubMed

Related Concept Videos

Amperometry: Overview01:10

Amperometry: Overview

Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
1.3K
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
1.3K
Secondary Active Transport01:32

Secondary Active Transport

One example of how cells use the energy contained in electrochemical gradients is demonstrated by glucose transport into cells. The ion vital to this process is sodium (Na+), which is typically present in higher concentrations extracellularly than in the cytosol. Such a concentration difference is due, in part, to the action of an enzyme "pump" embedded in the cellular membrane that actively expels Na+ from a cell. Importantly, as this pump contributes to the high concentration of...
8.9K
Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
669