Related Experiment Videos
Improved precision of interstitial brain tumor irradiation using the BRW CT stereotaxic guidance system
M D Sapozink1, J M Moeller, P N McDonald
1Division of Radiation Oncology, University of Utah Medical Center, Salt Lake City 84132.
International Journal of Radiation Oncology, Biology, Physics
|November 1, 1987
Abstract:
A technique is described which enables precise temporary interstitial volume implantation of brain tumors using a CT stereotaxic guidance system. This technique has the advantages of designing irregular isodose distributions during the preplanning stage. Although the preplanning stage can be time-consuming, this is performed while the patient is in the hospital room and CT scanner time, anesthesia time, and operating room time is minimized for individual patients.