Related Experiment Video
Updated: Dec 3, 2025

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
A comparative prospective study between stemmed versus an unstemmed tibial component in total knee arthroplasty in
Mohamed Mansour Elzohairy1, Sherif Mohamed Elaidy2, Mohamed Elsadek Attia2
1Faculty of Medicine, Zagazig University, Zagazig city, 4451, Ash Sharqia Governorate, Egypt. elzohairy.me@gmail.com.
Background:
There is no consensus in the literature regarding the patients with obesity who do well with TKA, or this group is at risk of a variety of complications. Implant choices between the two types of implants which either long or standard stem can improve the likelihood that a patient with obesity will achieve high scores for function and quality of life after TKA.
Methods:
This prospective clinical study included 200 patients who were categorized into two groups: group (1) traditional (standard) unstemmed cemented tibial tray (n = 100 patients) and group (2) stemmed cemented tibial tray with the cementless press-fit stem (n = 100 patients).
Results:
The average follow-up was (7.6 ± 1 years) (range from 6.5 up to 10 years). The average age of the stemmed group was 55.69 ± 8.45 and for the unstemmed group was 57.3 ± 7.8. The average BMI for the stemmed patients was 38.84 ± 3.89, while for the standard (unstemmed) group was 40.0 ± 3.95. Functional results showed significant improvement in both groups but more in the stemmed group (LS) as the difference and change between pre and post were more significant at long stem (P > 0.001).
Conclusion:
Based on our results, there were significant improvements in both groups either stemmed or unstemmed TKA but more in the stemmed group which had higher functional outcomes compared to the unstemmed group.
Level Of Evidence:
IV.
More Related Videos
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
07:33In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023