Related Experiment Video
Updated: Dec 3, 2025

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Simulated dimensional compatibility of uncuffed and cuffed tracheal tubes for selective endobronchial intubation in
Berthold Moser1,2, Michael Kemper1, Alexander Dullenkopf3
1Department of Anaesthesia, University Children's Hospital Zurich, Zurich, Switzerland.
Background:
Cuffed tracheal tubes have recently been recommended for selective endobronchial intubation to establish single-lung ventilation even in smaller children. This implies that, compared with uncuffed tracheal tubes, the cuffed tracheal tubes selected will be smaller and therefore have a shorter length. We hypothesized that cuffed tracheal tubes might be of insufficient length for selective endobronchial intubation if the tube cuff were fully immersed in the left or right mainstem bronchus.
Methods:
The distance from the proximal end of the tracheal tube to the upper border of the cuff in cuffed tracheal tubes and to the upper margin of the Murphy eye in uncuffed tracheal tubes, respectively, was assessed in sizes 3.0-7.0 mm internal diameter. The raw data sets of two previously performed studies obtained from 337 children aged from birth to 16 years, including the distances "teeth to tracheal tube tip" and "tracheal tube tip to carina," were used to calculate age-, weight-, and height-related data for the distance from "teeth to carina." Tracheal tube dimensions were compared with age-related distances from "teeth to carina," applying published recommendations for the selection of uncuffed and cuffed tracheal tubes for selective endobronchial intubation in children.
Results:
The differences between the length of the age-related tracheal tube and the tracheal tube insertion length required to guarantee full insertion of the tracheal tube cuff or the Murphy eye within the mainstem bronchus ranged from -3.5 to 52.6 mm in cuffed tracheal tubes and from 42.3 to 83.3 mm in uncuffed tracheal tubes.
Conclusions:
For many age groups of patients requiring selective endobronchial intubation, the lengths of cuffed tracheal tubes, in contrast to those of uncuffed tracheal tubes, were revealed to be critically short for safe taping outside the oral cavity with the cuff placed completely within the right or left mainstem bronchus.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...