Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique
Published on: March 24, 2023
Highly sensitive and flexible pressure sensor based on two-dimensional MoSe2 nanosheets for online wrist pulse
Pratik M Pataniya1, Sanjay A Bhakhar2, Mohit Tannarana2
1Department of Physical Science, P.D. Patel Institute of Applied Sciences, Charotar University of Science and Technology, CHRUSAT, Changa 388421, Gujarat, India.
Abstract:
The advancement of portable and flexible electronics that is integrated with multiple sensing functions has increasingly drawn considerable interest. The fabricated sensors would have the ability to sense multiple deformations like pressing, twisting and trivial vibrations such as pulses of wrist vibrations to mimic human skin. Presently, we implemented an easy, cost-effective and optimized fabrication technique for production of pressure sensors based on MoSe2 nanosheets coated on cellulose paper. The present sensor exhibits an incorporation of large pressure sensitivity of 18.42 kPa-1 in pressure range 0.001-0.5 kPa, 7.28 kPa-1 in pressure range 1-35 kPa and 2.63 kPa-1 in pressure range 40-100 kPa, working in broad pressure range (from 0.001 to 100 kPa) and long-term stability up to 200 deformation cycles at 2 kPa. The sensor showed excellent response towards the detection of vibrations of machines including cellular phone, compressor, etc. Besides, the sensor shows excellent environmental stability and exhibits immune piezo-resistive response to temperature variation.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring pulse
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: