Related Experiment Video
Updated: Dec 2, 2025

Imaging Features of Systemic Sclerosis-Associated Interstitial Lung Disease
Published on: June 16, 2020
High-frequency Ultrasound Assessment of Systemic Sclerosis Skin Involvement: Intraobserver Repeatability and
Victoria A Flower1, Shaney L Barratt2, Darren J Hart3
1V.A. Flower, Consultant Rheumatologist, MBBS, PhD, J.D. Pauling, Consultant Rheumatologist and Senior Lecturer, BMBS, PhD, Department of Rheumatology, Royal National Hospital for Rheumatic Diseases, Royal United Hospitals NHS Foundation Trust, Bath, Department of Pharmacy and Pharmacology, University of Bath, Bath; v.flower@nhs.net.
Objective:
The modified Rodnan skin score (mRSS) remains the preferred method for skin assessment in systemic sclerosis (SSc). There are concerns regarding high interobserver variability of mRSS and negative clinical trials utilizing mRSS as the primary endpoint. High-frequency ultrasound (HFUS) allows objective assessment of cutaneous fibrosis in SSc. We investigated the relationship between HFUS with both mRSS and dermal collagen.
Methods:
Skin thickness (ST), echogenicity, and novel shear wave elastography (SWE) were assessed in 53 patients with SSc and 15 healthy controls (HCs) at the finger, hand, forearm, and abdomen. The relationship between HFUS parameters with mRSS (n = 53) and dermal collagen (10 patients with SSc and 10 HCs) was investigated. Intraobserver repeatability of HFUS was calculated using intraclass correlation coefficients (ICCs).
Results:
HFUS assessment of ST (hand/forearm) and SWE (finger/hand) correlated with local mRSS at some sites. Subclinical abnormalities in ST, echogenicity, and SWE were present in clinically uninvolved SSc skin. Additionally, changes in echogenicity and SWE were sometimes apparent despite objectively normal ST on HFUS. ST, SWE, and local mRSS correlated strongly with collagen quantification (r = 0.697, 0.709, 0.649, respectively). Intraobserver repeatability was high for all HFUS parameters (ICCs for ST = 0.946-0.978; echogenicity = 0.648-0.865; and SWE = 0.953-0.973).
Conclusion:
Our data demonstrate excellent reproducibility and reassuring convergent validity with dermal collagen content. Detection of subclinical abnormalities is an additional benefit of HFUS. The observed correlations with collagen quantification support further investigation of HFUS as an alternative to mRSS in clinical trial settings.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...