Related Experiment Video
Updated: Dec 2, 2025

Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
The Effect of Dipping Tobacco on Pulse Wave Analysis among Adult Males
Areeg E Elemam1, Nisreen D Omer2,3, Neima M Ibrahim4
1Al Neelain University, Faculty of Medicine, Khartoum, Sudan P.O. Box 12702.
Background:
The current study investigated the effect of dipping tobacco (DT) use on arterial wall stiffness which is a known marker of increased risk of cardiovascular events.
Methods:
A case-control study which included 101 adult males was carried out in Al-Shaab Teaching Hospital. Blood pressure and pulse wave analysis parameters were recorded in 51 DT users (study group) before and after 30 minutes of placing tobacco and in 50 nontobacco users (control group). Anthropometric measurements were collected using data collection sheet. Data were entered into a computer and analyzed by using the software Statistical Package for the Social Sciences (SPSS) version 20 (SPSS Inc., Chicago, IL, USA).
Results:
At baseline measurements, heart rate (HR) was significantly lower in the study group compared to the control group (66.15 ± 9.21 vs. 72.87 ± 10.13 beats/min; P value ≤ 0.001). Subendocardial viability ratio (SEVR) was significantly higher in the study group compared to the control group (203.44 ± 30.34 vs. 179.11 ± 30.51%; P value ≤ 0.001). Acute effects of DT compared to pretobacco dipping showed significant increase in HR (72.50 ± 10.89 vs. 66.15 ± 9.21 beats/min; P value ≤ 0.001) and significant decrease in augmentation pressure (AP) (4.30 (2.30-8.00) vs. 3.30 (0.60-6.3) mmHg; P value ≤ 0.001), ejection duration (ED) (271.65 ± 19.42 vs. 279.53 ± 20.47 ms; P value ≤ 0.001), and SEVR (187.11 ± 29.81 vs. 203.44 ± 30.34; P value ≤ 0.001). Linear regression analysis for AP predictor showed that only HR and AIx@75 affect and predict the values of AP (Beta ± SE; -0.242 ± 0.019, P value ≤ 0.001; 0.685 ± 0.014, P value ≤ 0.001).
Conclusions:
Long-term use of DT was not associated with permanent changes in heart rate and blood pressure. Acute tobacco dipping caused an acute increase in heart rate and oxygen demands of myocardium.
Related Concept Videos
Special considerations while measuring pulse
Pulse
The pulse serves as a clinical...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Regulation of Pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...

