Terbium Excitation Spectroscopy as a Detection Method for Chromatographic Separation of Lanthanide-Binding
Wojciech Jurkowski1, Marcus Heilmann2, Anna M Becker3
1Werner Siemens Chair of Synthetic Biotechnology, Technical University of Munich (TUM), Lichtenbergstr. 4, D-85748 Garching, Germany.
None:
Studies of biosorption and bioaccumulation of heavy metals deal mostly with challenging, inhomogeneous, and complex materials. Therefore, most reports describe only application studies, while fundamental research is limited to indirect methods and speculations on the binding mechanisms. In this study, we describe a method for detecting and isolating heavy metal-binding biomolecules directly from crude extracts. The underlying principle is terbium sensitization and fluorescence excitation spectroscopy used offline after a chromatographic run. Compounds interacting with metal ions inevitably change the coordination sphere of terbium, which is reflected in the excitation spectrum leading to metal-specific luminescence. Main advantages of our approach include simple, fast, and inexpensive experiment design, nondestructive measurements, and detection limits far below 1 mg. Here, we have applied our method for three promising biosorbents (green algae, moss, and cyanobacterium) and obtained first information on the character of active compounds isolated from each species.
More Related Videos
08:31Luminescence Resonance Energy Transfer to Study Conformational Changes in Membrane Proteins Expressed in Mammalian Cells
Published on: September 16, 2014
09:38Fabrication Procedures and Birefringence Measurements for Designing Magnetically Responsive Lanthanide Ion Chelating Phospholipid Assemblies
Published on: January 3, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Gas Chromatography: Types of Detectors-II
Chromatographic Methods: Terminology