Related Experiment Video
Updated: Dec 2, 2025

Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
Association between Regional Tissue Oxygenation and Body Temperature in Term and Preterm Infants Born by Caesarean
Marlies Bruckner1,2, Lukas P Mileder1,2, Alisa Richter1
1Research Unit for Neonatal Micro- and Macrocirculation, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, 8036 Graz, Austria.
Abstract:
Body temperature (BT) management remains a challenge in neonatal intensive care, especially during resuscitation after birth. Our aim is to analyze whether there is an association between the BT and cerebral and peripheral tissue oxygen saturation (crSO2/cTOI and prSO2), arterial oxygen saturation (SpO2), and heart rate (HR). The secondary outcome parameters of five prospective observational studies are analyzed. We include preterm and term neonates born by Caesarean section who received continuous pulse oximetry and near-infrared spectroscopy monitoring during the first 15 min, and a rectal BT measurement once in minute 15 after birth. Four-hundred seventeen term and 169 preterm neonates are included. The BT did not correlate with crSO2/cTOI and SpO2. The BT correlated with the HR in all neonates (ρ = 0.210, p < 0.001) and with prSO2 only in preterm neonates (ρ = -0.285, p = 0.020). The BT was lower in preterm compared to term infants (36.7 [36.4-37.0] vs. 36.8 [36.6-37.0], p = 0.001) and prevalence of hypothermia was higher in preterm neonates (29.5% vs. 12.0%, p < 0.001). To conclude, the BT did not correlate with SpO2 and crSO2/cTOI, however, there was a weak positive correlation between the BT and the HR in the whole cohort and a weak correlation between the BT and prSO2 only in preterm infants. Preterm neonates had a statistically lower BT and suffered significantly more often from hypothermia during postnatal transition.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Factors Affecting Body Temperature
Factors may include:
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...