Related Experiment Video
Updated: Jul 30, 2026

Measurements of Long-range Electronic Correlations During Femtosecond Diffraction Experiments Performed on Nanocrystals of Buckminsterfullerene
Published on: August 22, 2017
Hard x-ray single-shot spectrometer at the European X-ray Free-Electron Laser
Naresh Kujala1, Wolfgang Freund1, Jia Liu1
1European X-Ray Free-Electron Laser Facility GmbH, Holzkoppel 4, 22869 Schenefeld, Germany.
Abstract:
The European X-ray Free-Electron Laser Facility in Germany delivers x-ray pulses with femtosecond pulse duration at a repetition rate of up to 4.5 MHz. The free-electron laser radiation is created by the self-amplified spontaneous emission (SASE) process, whose stochastic nature gives rise to shot-to-shot fluctuations in most beam properties, including spectrum, pulse energy, spatial profile, wavefront, and temporal profile. Each spectrum consisting of many spikes varies in width and amplitude that appear differently within the envelope of the SASE spectrum. In order to measure and study the SASE spectrum, the HIgh REsolution hard X-ray single-shot (HIREX) spectrometer was installed in the photon tunnel of the SASE1 undulator beamline. It is based on diamond gratings, bent crystals as a dispersive element, and a MHz-repetition-rate strip detector. It covers a photon energy range of 3 keV-25 keV and a bandwidth of 0.5% of the SASE beam. The SASE spikes are resolved with 0.15 eV separation using the Si 440 reflection, providing a resolving power of 60 000 at a photon energy of 9.3 keV. The measured SASE bandwidth is 25 eV. In this paper, we discuss the design specifications, installation, and commissioning of the HIREX spectrometer. The spectral results using Si (110), Si (111), and C (110) crystals are presented.
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab