Related Experiment Video
Updated: Dec 2, 2025

Custom-made Microdialysis Probe Design
Published on: July 21, 2015
Quantification of microdialysis related variability in humans: Clinical trial design recommendations
David Busse1, Philipp Simon2, Robin Michelet3
1Department of Clinical Pharmacy and Biochemistry, Institute of Pharmacy, Freie Universitaet Berlin, Berlin, Germany; Graduate Research Training Program PharMetrX, Berlin, Germany.
Objective:
Target-site concentrations obtained via the catheter-based minimally invasive microdialysis technique often exhibit high variability. Catheter calibration is commonly performed via retrodialysis, in which a transformation factor, termed relative recovery (RR), is determined. Leveraging RR values from a rich data set of a very large clinical microdialysis study, promised to contribute critical insight into the origin of the reportedly high target-site variability. The present work aimed (i) to quantify and explain variability in RR associated with the patient (including non-obese vs. obese) and the catheter, and (ii) to derive recommendations on the design of future clinical microdialysis studies.
Methods:
A prospective, age- and sex-matched parallel group, single-centre trial in non-obese and obese patients (BMI=18.7-86.9 kg/m2) was performed. 1-3 RR values were obtained in the interstitial fluid of the subcutaneous fat tissue in one catheter per upper arm of 120 patients via the retrodialysis method (nRR=1008) for a panel of drugs (linezolid, meropenem, tigecycline, cefazolin, fosfomycin, piperacillin and acetaminophen). A linear mixed-effects model was developed to quantify the different types of variability in RR and to explore the association between RR and patient body size descriptors.
Results:
Estimated RR was highest for acetaminophen (69.7%, 95%CI=65.0% to 74.3%) and lowest for piperacillin (40.4%, 95%CI=34.6% to 46.0%). The linear mixed-effects modelling analysis showed that variability associated with the patient (σ=15.9%) was the largest contributor (46.7%) to overall variability, whereas the contribution of variability linked to the catheter (σ=5.55%) was ~1/6 (16.8%). The relative contribution of residual unexplained variability (σ=12.0%, including intracatheter variability) was ~1/3 (36.4%). The limits of agreement of repeated RR determinations in a single catheter ranged from 0.694-1.64-fold (linezolid) to 0.510-3.02-fold (cefazolin). Calculated fat mass affected RR, explaining the observed lower RR in obese (ΔRRmean= -29.7% relative reduction) versus non-obese patients (p<0.001); yet only 15.8% of interindividual variability was explained by this effect. No difference in RR was found between catheters implanted into the left or right arm (p=0.732).
Conclusions:
Three recommendations for clinical microdialysis trial design were derived: 1) High interindividual variability underscored the necessity of measuring individual RR per patient. 2) The low relative contribution of intercatheter variability to overall variability indicated that measuring RR with a single catheter per patient is sufficient for reliable catheter calibration. 3) The wide limits of agreement from multiple RR in the same catheter implied an uncertainty of a factor of two in target-site drug concentration estimation necessitating to perform catheter calibration (retrodialysis sampling) multiple times per patient. To allow routine clinical use of microdialysis, research efforts should aim at further understanding and minimising the method-related variability. Optimised study designs in clinical trials will ultimately yield more informative microdialysis data and increase our understanding of this valuable sampling technique to derive target-site drug exposure.
More Related Videos
04:52Dynamic Continuous Blood Extraction from Rat Heart via Noninvasive Microdialysis Technique
Published on: September 13, 2022
08:17In Vivo Microdialysis Method to Collect Large Extracellular Proteins from Brain Interstitial Fluid with High-molecular Weight Cut-off Probes
Published on: September 26, 2018
Related Concept Videos
Dosage Regimen: Individualization
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Bioavailability Study Design: Healthy Subjects Versus Patients
Dialysis
Bioavailability Study Design: Single Versus Multiple Dose Studies
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant