Purpose:
To compare the outcomes of microcalcifications recalled on full-field digital (FFDM) and FFDM and combined tomosynthesis (Combo) to synthetic (SM) screening mammograms.
Method:
We reviewed medical records, radiology, and pathology reports of all patients found to have abnormal calcifications requiring further evaluation on mammography screening at our institution between 11/1/2016-11/1/2018 and collected patient demographics, calcification morphology and distribution, and mammography technique (SM, FFDM, or Combo). We used biopsy pathology or at least 1-year imaging follow-up to establish overall diagnostic outcome (benign or malignant). Fisher's exact test was used to compare validation rates at diagnostic work-up, BI-RADS category, and final outcome of calcifications identified on each screening technique. T-test was used for continuous variables.
Results:
Of 699 calcifications in 596 women recalled, 176 (30%) of 596 were from SM and 420 (70%) FFDM/Combo. There was a significantly higher rate of calcifications unvalidated at diagnostic work-up for SM compared to FFDM/Combo (0.8% vs. 10%, p < 0.0001). SM calcifications were more likely to receive BI-RADS 2/3 at diagnostic work-up compared to FFDM/Combo ones (55% vs. 42%, p = 0.003). Of 346 (49%) calcifications that underwent biopsy, 88 (25%) were malignant (36% of SM vs. 22% of FFDM/Combo, OR:0.5 [95% CI: 0.3, 0.8] p = 0.01). Of 622 lesions with established diagnostic outcome, there was no difference between having an overall benign or malignant outcome between SM and FFDM/Combo (17% vs. 13%, OR: 0.8 [95% Cl: 0.5, 1.2] p = 0.27).
Conclusions:
Synthetic tomosynthesis screening results in a higher rate of false positive and unvalidated calcification recalls compared to FFDM/Combo.