Related Experiment Video
Updated: Dec 2, 2025

Author Spotlight: Advancements in 3D Optical Imaging for Comprehensive Body Composition Assessment in Modern Research
Published on: June 7, 2024
Personalized computed tomography - Automated estimation of height and weight of a simulated digital twin using a 3D
Frederik Geissler1,2, Rafael Heiß2, Markus Kopp2
1Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen, Germany.
Purpose:
The aim of this study was to develop an algorithm for automated estimation of patient height and weight during computed tomography (CT) and to evaluate its accuracy in everyday clinical practice.
Materials And Methods:
Depth images of 200 patients were recorded with a 3D camera mounted above the patient table of a CT scanner. Reference values were obtained using a calibrated scale and a measuring tape to train a machine learning algorithm that fits a patient avatar into the recorded patient surface data. The resulting algorithm was prospectively used on 101 patients in clinical practice and the results were compared to the reference values and to estimates by the patient himself, the radiographer and the radiologist. The body mass index was calculated from the collected values for each patient using the WHO formula. A tolerance level of 5 kg was defined in order to evaluate the impact on weight-dependent contrast agent dosage in abdominal CT.
Results:
Differences between values for height, weight and BMI were non-significant over all assessments (p > 0.83). The most accurate values for weight were obtained from the patient information (R² = 0.99) followed by the automated estimation via 3D camera (R² = 0.89). Estimates by medical staff were considerably less precise (radiologist: R² = 0.78, radiographer: R² = 0.77). A body-weight dependent dosage of contrast agent using the automated estimations matched the dosage using the reference measurements in 65 % of the cases. The dosage based on the medical staff estimates would have matched in 49 % of the cases.
Conclusion:
Automated estimation of height and weight using a digital twin model from 3D camera acquisitions provide a high precision for protocol design in computer tomography.
Key Points:
· Machine learning can calculate patient-avatars from 3D camera acquisitions.. · Height and weight of the digital twins are comparable to real measurements of the patients.. · Estimations by medical staff are less precise.. · The values can be used for calculation of contrast agent dosage..
Citation Format:
· Geissler F, Heiß R, Kopp M et al. Personalized computed tomography - Automated estimation of height and weight of a simulated digital twin using a 3D camera and artificial intelligence. Fortschr Röntgenstr 2021; 193: 437 - 445.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography

