Related Experiment Video
Updated: Dec 2, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Dielectric Model of Carbon Nanofiber Reinforced Concrete
Zhi-Hang Wang1, Jin-Yu Xu1,2, Er-Lei Bai1
1Department of Airfield and Building Engineering, Air Force Engineering University, Xi'an 710038, China.
Abstract:
The formula describing the relationship between the dielectric constant of a composite and the dielectric constants or volume rates of its components is called a dielectric model. The establishment of a cement concrete dielectric model is the basic and key technique for applying electromagnetic wave technology to concrete structure quality testing and internal damage detection. To construct the dielectric model of carbon nanofiber reinforced concrete, the carbon nanofiber reinforced concrete was measured by the transmission and reflection method for dielectric constant ε, and ε,, in the frequency range of 1.7~2.6 GHz as the fiber content was 0, 0.1%, 0.2%, 0.3% and 0.5%. Meanwhile, concrete was considered as a composite material composed of three phases, matrix (mortar), coarse aggregate (limestone gravel) and air, and the dielectric constants and volume rates of each component phase were tested. The Brown model, CRIM (Complex Refractive Index Model) model and Looyenga model commonly used in composite materials were modified based on the experimental data, suitable dielectric models of carbon nanofiber reinforced concrete were constructed, and a reliability check and error analysis of the modified models were carried out. The results showed that the goodness of fit between the calculated curves based on the three modified models and the measured curves was very high, the accuracy and applicability were very strong and the variation rule for the dielectric constant of carbon nanofiber concrete with the frequency of electromagnetic wave could be described accurately. For ε, and ε,,, the error between the dielectric constant calculated by the three modified models and the corresponding measured values was very small. For the dielectric constant ε,, the average error was maintained below 1.2%, and the minimum error was only 0.35%; for the dielectric constant ε,,, the average error was maintained below 3.55%.
Related Concept Videos
Fiber Reinforced Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Permeability of Concrete
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Accelerated Curing of Concrete

