Related Experiment Video
Updated: Dec 2, 2025

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Navigated Placement of Two Odontoid Screws Using the O-Arm Navigation System: A Technical Case Report
Clara K Starkweather1, Ramin Morshed1, Caleb Rutledge1
1Neurological Surgery, University of California San Francisco, San Francisco, USA.
Abstract:
Odontoid fractures are common cervical spine fractures and lead to atlantoaxial instability depending on their type. Fractures through the base of the odontoid neck are considered for surgery. While the management of these fractures is controversial and may include external immobilization or posterior fusion, an odontoid screw offers the advantages of directly crossing the fracture site while preserving motion at C1-2. Although intraoperative navigation is routinely utilized in spine surgery, there are few reports of navigated anterior odontoid screw placement. In this report, we describe the safe and accurate placement of two anterior odontoid screws using the O-arm navigation system in an octogenarian with a type II odontoid fracture. Details of the technical approach are also provided. The follow-up imaging at three months confirmed the healing of the fracture. Intraoperative navigation using the O-arm system allows for safe and accurate placement of two odontoid screws.