Related Experiment Video
Updated: Dec 2, 2025

Pure Shift Nuclear Magnetic Resonance: a New Tool for Plant Metabolomics
Published on: July 31, 2021
Return of the Big Glitcher: NICER timing and glitches of PSR J0537-6910
Wynn C G Ho1, Cristóbal M Espinoza2, Zaven Arzoumanian3
1Department of Physics and Astronomy, Haverford College, 370 Lancaster Avenue, Haverford, PA, 19041, USA.
Abstract:
PSR J0537-6910, also known as the Big Glitcher, is the most prolific glitching pulsar known, and its spin-induced pulsations are only detectable in X-ray. We present results from analysis of 2.7 years of NICER timing observations, from 2017 August to 2020 April. We obtain a rotation phase-connected timing model for the entire timespan, which overlaps with the third observing run of LIGO/Virgo, thus enabling the most sensitive gravitational wave searches of this potentially strong gravitational wave-emitting pulsar. We find that the short-term braking index between glitches decreases towards a value of 7 or lower at longer times since the preceding glitch. By combining NICER and RXTE data, we measure a long-term braking index n = -1.25 ± 0.01. Our analysis reveals 8 new glitches, the first detected since 2011, near the end of RXTE, with a total NICER and RXTE glitch activity of 8.88 × 10-7 yr-1. The new glitches follow the seemingly unique time-to-next-glitch-glitch-size correlation established previously using RXTE data, with a slope of 5 d microHz-1. For one glitch around which NICER observes two days on either side, we search for but do not see clear evidence of spectral nor pulse profile changes that may be associated with the glitch.
More Related Videos
Related Concept Videos
Phasor Arithmetics
When the derivative of a sinusoid is taken in the time domain, it transforms into its corresponding phasor multiplied by j-omega (jω) in the phasor domain, where j is the imaginary unit, and ω is the angular...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Errors in Global Positioning System

