Related Experiment Video
Updated: Dec 2, 2025

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Endovascular Outcomes in Aortic Arch Repair with Double and Triple Parallel Stent Grafts
Baolei Guo1, Daqiao Guo1, Bin Chen1
1Department of Vascular Surgery, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai 200032, China.
Purpose:
To report early and midterm outcomes of treating thoracic aortic aneurysm (TAA) and aortic dissection (AD) involving zone 1 and zone 0 with multiple parallel stent grafts (PSGs).
Materials And Methods:
From February 2011 to August 2018, 31 of 1,806 patients (1.7%) who underwent thoracic endovascular aortic repair (TEVAR) with double PSGs (DPSGs) (n = 20) or triple PSGs (TPSGs) (n = 11) were retrospectively reviewed. Procedures were performed in high-risk patients who had TAA or AD involving zone 1 or zone 0.
Results:
Fifteen patients (48.4%) who presented with symptomatic or impending rupture underwent urgent or emergent TEVAR with DPSGs or TPSGs. Nineteen patients (61.3%) were treated for zone 0 disease. Technical and clinical success rates were 70.0% for DPSG cohort and 45.5% for TPSG cohort. Intraoperative type Ia endoleak was observed in 30% of DPSG cohort and 45.5% of TPSG cohort. One patient in the DPSG cohort died of aortic sinus rupture intraoperatively. Minor stroke during the 30-day postoperative period was more frequent in the TPSG cohort (P = .042). Mean duration of follow-up was 28.9 months ± 17.7. The TPSG cohort had a higher incidence of major adverse events (72.7% vs 25.0%, P = .021). The most common adverse events were endoleaks (12.9%), endograft migration (9.7%), PSG stenosis or occlusion (6.5%), retrograde dissection (6.5%), and stroke (3.2%). Endograft migrations were more common in TPSG cohort (27.3%, P = .037). Overall mortality rate was 16.1% (5/31) perioperatively and during follow-up. There were no statistical differences in overall survival and reintervention-free survival.
Conclusions:
In the context of TEVAR with multiple PSGs for aortic arch repair, TPSGs may have a high risk of major complications.