Related Experiment Video
Updated: Dec 1, 2025

Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
Local temperature control improves the accuracy of cardiac output estimation using lung-to-finger circulation time
Tomoyuki Tobushi1, Kazuyuki Matsushita2, Kouta Funakoshi3
1Department of Cardiovascular Medicine, Saiseikai Futsukaichi Hospital, Chikushino, Japan.
Abstract:
As timely measurement of the cardiac index (CI) is one of the key elements in heart failure management, a noninvasive, simple, and inexpensive method of estimating CI is keenly needed. We attempted to develop a new device that can estimate CI from the data of lung-to-finger circulation time (LFCT) obtained after a brief breath hold in the awake state. First, we attempted to estimate CI from the LFCT value by utilizing the correlation between 1/LFCT and CI estimated with MRI. Although we could obtain LFCT from 45 of 53 patients with cardiovascular diseases, we could not find the anticipated relation between 1/LFCT and CI. However, we realized that when we adopted only LFCT from patients with a finger temperature of ≥31°C, we could obtain a consistent and clear correlation with CI (correlation coefficient, r = .81). Thus, we next measured LFCT before and after warming the forearm. We found that LFCT decreased after the local temperature increased (from 27.5 ± 13.6 to 18.4 ± 5.3 s, p < 0.01). The correlation between the inverse of LFCT and CI improved after warming (1/LFCT vs. CI, from r = .69 to r = .82). The final Bland-Altman analysis between the measured and estimated CI values revealed that the bias and precision were -0.05 and 0.37 L min-1 m-2 , respectively, and the percentage error was 34.3%. This study clarified that estimating CI using a simple measurement of LFCT is feasible in most patients and a low fingertip temperature strongly affects the CI-1/LFCT relationship, causing an error that can be corrected by proper local warming.
More Related Videos
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...