Related Experiment Video
Updated: Dec 1, 2025

A Novel Method to Determine the Longitudinal Antibacterial Activity of Drug-Eluting Materials
Published on: March 3, 2023
Development and validation of voltammetric method for determination of amoxicillin in river water
Marcia Gabriela Pianaro Valenga1, Maria Lurdes Felsner1, Carolina Ferreira de Matos2
1Universidade Estadual Do Centro-Oeste, Departamento de Química, Guarapuava, Paraná, 85040-080, Brazil.
Abstract:
Amoxicillin is an antibiotic that can accumulate in aquatic environments and lead to the development of resistant bacteria; thus, its determination is of great importance. In this study, a glassy carbon electrode modified with reduced graphene oxide and Nafion was used as a sensor in a square-wave voltammetry method for determination of amoxicillin in river water samples from Guarapuava city, Brazil. The method was validated, using parameters and statistical tools recommended by the validation guidelines, in the range of 1.8-5.4 μmol L-1 (r = 0.922 and R2 = 85.1%). The analytical curve was constructed using external standard calibration in pure electrolyte, since the matrix effect was not significant. Results of linear regression analysis, lack of fit test and analysis of the residual plots pointed that the linear regression was significant, without lack of fit of linear model and that the variances had homoscedastic distribution. Both coefficients of regression curve were significant and, thus, they were included in the regression equation: Response = 7.0 + 3.5CAMX. The limits of detection and quantification were 0.36 and 1.2 μmol L-1, respectively. The method was selective towards interferents such as humic acids and benzylpenicillin. The relative standard deviations for repeatability and intermediate precision were adequate according to the limits established in literature. The mean recoveries were statistically equal to those obtained through a comparative chromatography method, so, the accuracy of the method was also adequate. Therefore, the method can be applied to the voltammetric determination of amoxicillin in river water, affording reliable and consistent measurements.
More Related Videos
08:58Isolation and Identification of Waterborne Antibiotic-Resistant Bacteria and Molecular Characterization of their Antibiotic Resistance Genes
Published on: March 3, 2023
08:30One-day Workflow Scheme for Bacterial Pathogen Detection and Antimicrobial Resistance Testing from Blood Cultures
Published on: July 9, 2012
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Amperometry: Overview
Voltammetric Techniques: Pulse Voltammetry
Data Validation
Key parameters for method validation include:
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...