Related Experiment Video
Updated: Dec 1, 2025

Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
Automatic COVID-19 lung infected region segmentation and measurement using CT-scans images
Adel Oulefki1, Sos Agaian2, Thaweesak Trongtirakul3
1Centre de Développement des Technologies Avancées - CDTA, PO. Box 17 Baba Hassen, Algiers 16081, Algeria.
Abstract:
History shows that the infectious disease (COVID-19) can stun the world quickly, causing massive losses to health, resulting in a profound impact on the lives of billions of people, from both a safety and an economic perspective, for controlling the COVID-19 pandemic. The best strategy is to provide early intervention to stop the spread of the disease. In general, Computer Tomography (CT) is used to detect tumors in pneumonia, lungs, tuberculosis, emphysema, or other pleura (the membrane covering the lungs) diseases. Disadvantages of CT imaging system are: inferior soft tissue contrast compared to MRI as it is X-ray-based Radiation exposure. Lung CT image segmentation is a necessary initial step for lung image analysis. The main challenges of segmentation algorithms exaggerated due to intensity in-homogeneity, presence of artifacts, and closeness in the gray level of different soft tissue. The goal of this paper is to design and evaluate an automatic tool for automatic COVID-19 Lung Infection segmentation and measurement using chest CT images. The extensive computer simulations show better efficiency and flexibility of this end-to-end learning approach on CT image segmentation with image enhancement comparing to the state of the art segmentation approaches, namely GraphCut, Medical Image Segmentation (MIS), and Watershed. Experiments performed on COVID-CT-Dataset containing (275) CT scans that are positive for COVID-19 and new data acquired from the EL-BAYANE center for Radiology and Medical Imaging. The means of statistical measures obtained using the accuracy, sensitivity, F-measure, precision, MCC, Dice, Jacquard, and specificity are 0.98, 0.73, 0.71, 0.73, 0.71, 0.71, 0.57, 0.99 respectively; which is better than methods mentioned above. The achieved results prove that the proposed approach is more robust, accurate, and straightforward.
More Related Videos
03:38Unilateral Lung Volume Analysis Using Micro-CT for Enhanced Assessment of Pulmonary Fibrosis in Preclinical Models
Published on: June 20, 2025
07:53Author Spotlight: Advancing 3D Modeling for Enhanced Diagnosis and Treatment of Pulmonary Nodules in Early-Stage Lung Cancer
Published on: October 13, 2023