Related Experiment Video
Updated: Dec 1, 2025

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Dose-Volume Predictors of Radiation Pneumonitis After Lung Stereotactic Body Radiation Therapy (SBRT): Implications
Vitali Moiseenko1, Jimm Grimm2, Ellen Yorke3
1Radiation Medicine and Applied Sciences, University of California San Diego Moores Cancer Center, La Jolla, USA.
Abstract:
Background and purpose Recently published HyTEC report summarized lung toxicity data and proposed guidelines of mean lung dose (MLD) <8 Gy and normal lung receiving at least 20 Gy, V20Gy<10-15% to avoid lung toxicity. Support for preferred use of a particular dosimetric parameter has been limited. We performed a detailed dose-volume analysis of data on radiation pneumonitis (RP) following lung stereotactic body radiation therapy (SBRT) to search for parameters showing the strongest correlation with RP. Materials and methods Two patient cohorts (primary and metastatic lung tumor patients) from previously reported studies were analyzed. Total number of patients was 96, and incidence of grade ≥2 RP was 13.5% (13/96). Fitting to the logistic function was performed to investigate correlation between incidence of RP and reported dosimetric and volumetric parameters. Another independent cohort was used to explore correlation between dosimetric parameters. Results Among normal lung parameters (MLD and reported Vx), only MLD consistently showed significant correlation with incidence of RP. Gross tumor volume (GTV), internal target volume, planning target volume (PTV), and minimum dose covering 95% of GTV or PTV did not show statistical significance. A significant correlation between reported Vx and MLD was observed in all cohorts. Conclusions In considering tumor- and target-specific (e.g., GTV, PTV) and normal lung-specific (e.g., MLD, Vx) metrics, MLD was the only parameter that consistently correlated with incidence of RP across both cohorts. Because SBRT planning constraints allow small normal lung volumes to receive high doses, utility of MLD is not obvious. The parallel structure of lung is one possible explanation, but correlation between dosimetric parameters obscures elucidation of the preferred or mechanistically based parameter to guide radiotherapy planning.
More Related Videos
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Pneumothorax-II
Clinical Manifestations: