Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Total-transfer comprehensive three-dimensional gas chromatography with time-of-flight mass spectrometry
Timothy J Trinklein1, Sonia Schöneich1, Paige E Sudol1
1Department of Chemistry, Box 351700, University of Washington, Seattle, WA 98195, USA.
Abstract:
Although comprehensive two-dimensional (2D) gas chromatography (GC × GC) is a powerful technique for complex samples, component overlap remains likely. An intriguing route to address this challenge is to utilize the additional peak capacity and chemical selectivity provided by comprehensive three-dimensional (3D) gas chromatography (GC3), especially with time-of-flight mass spectrometry detection (GC3-TOFMS). However, the GC3-TOFMS instrumentation reported to date has employed one or both modulators with a duty cycle < 100%, making the potential gain in detection sensitivity over GC × GC modest, or perhaps even worse. Herein, we describe instrumentation for GC3-TOFMS in which both modulators provide total-transfer (100% duty cycle). Specifically, the instrument is based on the facile modification of a commercial thermally modulated comprehensive GC × GC-TOFMS platform for modulation from the 1D column to the 2D column, with recently described dynamic pressure gradient modulation (DPGM) as the second modulator from the 2D column to the 3D column, which is a total-transfer flow modulation technique. Area measurements of 1D peaks are compared to the sum of 3D peak areas to validate the assumption that total-transfer from 1D to 3D is accomplished. Additionally, peak heights were amplified by as high as a factor of 177 (x̅ = 130, s = 47) via comparison of 1D peak heights to the maximum 3D peak heights. Column selection is explored, with emphasis on the resulting peak width-at-base on each dimension and usage of 3D space as evaluation metrics. Using a nonpolar × polar × ionic liquid column combination, an effective peak capacity which considers modulation-induced broadening as high as 32,300 for select analytes was achieved (x̅ = 19,900, s = 10,700). The analytical benefits of employing three selective phases, mass spectrometry detection, and total-transfer modulation are explored with separations of a metabolomics-type sample, i.e., derivatized porcine serum, and a jet fuel spiked with various sulfur-containing compounds.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Gas Chromatography: Types of Detectors-II