Related Experiment Video
Updated: Dec 1, 2025

Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
Nebulization dielectric barrier discharge ionization mass spectrometry: Rapid and sensitive analysis of acenaphthene
Jing He1, Wenxin Wang2, Hong Zhang2
1State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang, 150090, PR China; School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong, 264209, PR China; School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, 150090, PR China.
Abstract:
A rapid, simple and sensitive method was proposed for low-polar acenaphthene analysis by coupling nebulization with dielectric barrier discharge ionization (N-DBDI). The sample solution was nebulized followed by heating and converted to be gas-phase analyte molecules prior to DBDI. This boosts the collision efficiency of analyte molecules with reactive species and thus the sensitivity, and the high-velocity gas from nebulization guides ions directed to the MS inlet without deflection. The dependence of sensitivity on the operation parameters was systematically investigated. The LOD and LOQ of acenaphthene were determined to be 0.61 ng/L and 2.05 ng/L, respectively, which were superior approximately 30 folds compared to those obtained by other methods. Parameters, including accuracy, precision, reproducibility and utility, were tested to further evaluate the performance of N-DBDI. Real environmental samples, including river water, initial rainwater and mineral water, were analyzed with good accuracy (93.61-103.50%) and satisfactory precision (RSD ≤ 8.92%). These findings suggest that the N-DBDI allows the determination of non/low-polar species at sub-pg/mL possible, and would benefit for the non/low-polar species analysis in real environmental samples.
More Related Videos
07:53Analysis of Complex Molecules and Their Reactions on Surfaces by Means of Cluster-Induced Desorption/Ionization Mass Spectrometry
Published on: March 1, 2020
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...