Related Experiment Video
Updated: Dec 1, 2025

Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024
Accuracy and reliability of maxillary digital model (MDM) superimposition in evaluating teeth movement in adults
Yichen Pan1, Xin Wang1, Fanfan Dai2
1Department of Orthodontics, School and Hospital of Stomatology, 22# Zhongguancun Avenue South, Haidian District, Beijing, People's Republic of China.
Abstract:
Superimposition of 3D maxillary digital dental models of different time points based on palatal vault region has been used to evaluate tooth movement during orthodontic treatment. This study evaluated the accuracy and reliability of 3D maxillary digital model (MDM) superimposition in adults by comparing it with CBCT maxillary superimposition. In CBCT maxillary superimposition, voxel-based superimposition was firstly conducted, and MDMs were matched with corresponding CBCT models (CBCT-MDM superimposition). MDM superimposition (palatal vault regional superimposition) were performed on another pair of pre- and posttreatment MDMs. The position and orientation of upper first molars (U6s) and upper central incisors (U1s) on the posttreatment MDMs were compared to assess the accuracy of the MDM superimposition methods. The reliability was validated in both MDM superimposition and CBCT maxillary superimposition. In terms of accuracy, the average linear deviations in U6 and U1 positions were less than ± 0.3 mm, the average angular deviations of U6s and U1s were less than ± 0.2°, both have no significant difference from zero. The ICCs for MDM superimposition ranged from 0.85 to 0.99. The ICCs for CBCT-MDM superimposition were larger than 0.99 in all items. MDM superimposition was an efficient, accurate and reliable method for evaluating teeth movement in adults, although its reliability is slightly lower than CBCT maxillary superimposition.

