Non-Invasive Electrochemical Biosensors Operating in Human Physiological Fluids
Magnus Falk1, Carolin Psotta1,2, Stefan Cirovic1
1Department of Biomedical Science, Faculty of Health and Society, and Biofilms-Research Center for Biointerfaces, Malmö University, 20506 Malmö, Sweden.
Sensors (Basel, Switzerland)
|November 11, 2020
Summary
Non-invasive electrochemical biosensors in bodily fluids like tears and sweat offer convenient healthcare. Addressing current challenges can revolutionize clinical and self-monitoring practices.
Area of Science:
- Biomedical Engineering
- Analytical Chemistry
- Wearable Technology
Background:
- Non-invasive healthcare technologies are crucial for cost-effective and convenient patient monitoring.
- Electrochemical biosensors offer a promising avenue for real-time analysis of physiological fluids.
Purpose of the Study:
- To overview recent advancements in non-invasive electrochemical biosensors.
- To discuss challenges and requirements for biosensors operating in human physiological fluids.
Main Methods:
- Review of electrochemical techniques including amperometry, coulometry, cyclic voltammetry, and impedance spectroscopy.
- Analysis of biosensor performance in secreted human physiological fluids (tears, sweat, saliva, urine).
Main Results:
- Significant progress in developing non-invasive electrochemical biosensors for various bodily fluids.
- Identification of key challenges such as sensor stability, calibration, and multiplexing.
Conclusions:
- Non-invasive biosensing in bodily fluids is complex but holds transformative potential.
- Overcoming current limitations can disrupt traditional clinical diagnostics and personal health monitoring.
Related Concept Videos
Potentiometry: Membrane Electrodes
1.3K
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
1.3K
Interfacial Electrochemical Methods: Overview
654
Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...