Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Retinal ischemic perivascular lesions in cortical cerebral infarction: a comparison against controls.

Eye (London, England)·2026
Same author

Daylight saving time transition and new-onset retinal vascular disease: a nationwide cohort study.

Scientific reports·2026
Same author

Surgeon-Patient Sex Concordance and Postoperative Outcomes in Cataract Surgeries: A 16-Year Retrospective Cohort Study.

Clinical ophthalmology (Auckland, N.Z.)·2026
Same author

Retinal Ischemic Perivascular Lesions in Pulmonary Hypertension: Retinal Biomarkers Informing Systemic Microvascular Dysfunction.

Translational vision science & technology·2026
Same author

Functional, molecular, and digital measurements of biological age.

The Journal of clinical investigation·2026
Same author

Tracking the big picture during wartime: A national trauma registry perspective.

The journal of trauma and acute care surgery·2026

Related Experiment Video

Updated: Dec 1, 2025

Optimization of the Retinal Vein Occlusion Mouse Model to Limit Variability
07:23

Optimization of the Retinal Vein Occlusion Mouse Model to Limit Variability

Published on: August 6, 2021

3.0K

Contrast Sensitivity Testing in Retinal Vein Occlusion Using a Novel Stimulus.

Shubhendu Mishra1, Nenita Maganti1, Natalie Squires1

  • 1Department of Ophthalmology, Northwestern University, Chicago, IL, USA.

Translational Vision Science & Technology
|November 11, 2020
PubMed
Summary

A new tool, the motion diamond stimulus (MDS), effectively measures contrast sensitivity (CS) in patients with retinal vein occlusions (RVOs), revealing impaired visual function.

Keywords:
contrast sensitivityretinal ischemiavisual adaptation

More Related Videos

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
07:11

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential

Published on: May 25, 2020

6.7K
In Vivo Vascular Injury Readouts in Mouse Retina to Promote Reproducibility
07:35

In Vivo Vascular Injury Readouts in Mouse Retina to Promote Reproducibility

Published on: April 21, 2022

2.5K

Related Experiment Videos

Last Updated: Dec 1, 2025

Optimization of the Retinal Vein Occlusion Mouse Model to Limit Variability
07:23

Optimization of the Retinal Vein Occlusion Mouse Model to Limit Variability

Published on: August 6, 2021

3.0K
Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
07:11

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential

Published on: May 25, 2020

6.7K
In Vivo Vascular Injury Readouts in Mouse Retina to Promote Reproducibility
07:35

In Vivo Vascular Injury Readouts in Mouse Retina to Promote Reproducibility

Published on: April 21, 2022

2.5K

Area of Science:

  • Ophthalmology
  • Visual Neuroscience
  • Medical Devices

Background:

  • Visual complaints in retinal diseases often extend beyond standard visual acuity measurements.
  • Contrast sensitivity (CS) is a crucial aspect of visual function that may be affected in retinal conditions.
  • Existing methods for CS assessment may not fully capture the nuances of visual impairment.

Purpose of the Study:

  • To evaluate a novel tool, the motion diamond stimulus (MDS), for assessing contrast sensitivity (CS).
  • To determine if the MDS can detect differences in CS between patients with treated unilateral retinal vein occlusions (RVOs) and healthy controls.
  • To compare the performance of the MDS with established CS tests like the Pelli-Robson (PR) chart.

Main Methods:

  • Patients with treated unilateral RVOs (n=20) and healthy controls (n=20) were recruited.
  • Contrast sensitivity was assessed using the MDS, Pelli-Robson (PR) chart, and the National Eye Institute's Visual Function Questionnaire (VFQ-25).
  • The MDS provided two parameters: α (contrast threshold) and β (visual contrast system adaptability).

Main Results:

  • A significant difference in PR log CS scores (P=0.0001) and MDS α values (P=0.01) was found between RVO eyes and control eyes.
  • The MDS α values correlated with PR scores, indicating impaired contrast sensitivity threshold in RVO patients.
  • No significant difference in MDS β values (P=0.39) was observed, suggesting preserved visual system adaptability.

Conclusions:

  • The MDS is a promising tool for quantifying contrast sensitivity deficits in patients with RVO.
  • The study results suggest that while contrast sensitivity thresholds are impaired in RVO, visual system adaptability may be maintained.
  • The MDS may offer a more comprehensive assessment of visual function than traditional methods, aiding in the detection of subtle changes in retinal disease progression.