Related Experiment Video
Updated: Dec 1, 2025

Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
High-end versus Low-end Thermal Imaging for Detection of Arterial Perforators
Magnús Pétur Bjarnason Obinah1, Monica Nielsen2, Lisbet Rosenkrantz Hölmich1,3
1Department of Plastic Surgery, Herlev and Gentofte University Hospital, Copenhagen, Denmark.
Background:
Thermal imaging was first reported as a method for detection of arterial perforators in 1968 and has since been shown to be an extremely accurate way to assess perforators with an audible Doppler signal, using high-end professional thermal cameras. This technology has recently become easily accessible with the advent of smartphone-compatible, low-end thermal cameras. Several groups have reported on the use of these devices in the pre-, intra-, and postoperative phase, yet there have been few attempts to validate them against existing methods or compare them with high-end thermal cameras.
Methods:
The aim of this study was to compare a low-end smartphone-compatible thermal camera, the FLIR ONE Pro (ONEPro), priced US $400, with a high-end thermal camera the FLIR A35sc (A35sc), priced US $5000, for the detection of arterial perforators on the anterolateral thigh, using a handheld Doppler and Color Doppler Ultrasound to verify the results.
Results:
We examined 23 thighs in 13 healthy volunteers and identified a total of 779 hotspots using both cameras. The A35sc identified on average 33.5 hotspots per thigh. The ONEPro identified on average 31.5 hotspots per thigh. Using a handheld Doppler, we confirmed 95.9% of hotspots identified with the ONEPro and 95.8% of hotspots identified with the A35sc. Using Color Doppler Ultrasound, we confirmed 95% of hotspots identified using the ONEPro and 94.9% of hotspots identified with the A35sc.
Conclusion:
While the high-end camera identified slightly more hotspots, verification data were very similar for the 2 cameras, and for clinical purposes these differences are negligible.
More Related Videos
09:56Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
Published on: November 4, 2014
05:26Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
Published on: January 7, 2019
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...