Development of image quality related reference doses called acceptable quality doses (AQD) in paediatric CT exams in
Mohammad Hassan Kharita1, Huda AlNaemi2, Vishwanatha Kini2
1Hamad Medical Corporation, Occupational Health and Safety, Radiation Safety Section, Doha, Qatar. mhharita@hamad.qa.
Objectives:
To describe first experience of integrating assessment of image quality in paediatric X-ray computed tomography (CT) with analysis of the radiation dose indices to develop reference doses called acceptable quality dose (AQD).
Methods:
Image quality was scored by the radiologists at a tertiary care hospital in Qatar on a scale of 0 to 4 using the recently published scoring criteria. The patients undergoing head, chest and abdomen CT were divided in different weight groups as follows: < 5 kg, 5-< 15 kg, 15-< 30 kg, 30-< 50 kg, 50-< 80 kg and > 80 kg. The images that were clinically acceptable (score of 3) were included for assessment of median values of CTDIvol and DLP to obtain AQDs in different weight groups.
Results:
After initial training in image quality scoring of CT images of 49 patients by three radiologists, the study on 715 patients indicated 665 studies (93%) were clinically acceptable as per scoring criteria. The median CTDIvol values for the above weight groups were 16, 20, 22, 22, 27 and 27 mGy and the median DLP values for these weight groups were 271, 377, 463, 486, 568 and 570 mGy cm, respectively, for head CT. Similar values are presented for chest and abdomen CTs.
Conclusions:
The first ever experience of starting with image quality assessment and integrating it with analysis of dose indices to obtain AQD values shall provide a workable model for others and values for comparison within the facility and in other facilities leading to optimisation.
Key Points:
• The first study to integrate image quality assessment with analysis of patient dose indices shows feasibility for routine practice in other centres. • The values of acceptable quality dose (AQD) were provided for head, chest and abdomen CT of children divided into weight groups rather than age. They shall act as reference values for future studies. • Verification of our findings on proportional increase in exposure parameters (CTDIvol and DLP) with weight by other investigators shall be helpful.
More Related Videos
10:12Differentiation of Human Pluripotent Stem Cells Into Pancreatic Beta-Cell Precursors in a 2D Culture System
Published on: December 16, 2021
10:31Robust Differentiation of Human iPSCs into a Pure Population of Adipocytes to Study Adipocyte-Associated Disorders
Published on: February 9, 2022
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography