Related Experiment Video
Updated: Dec 1, 2025

Measurement of Aerosols Optical Thickness of the Atmosphere using the GLOBE Handheld Sun Photometer
Published on: May 29, 2019
Validation of OMI-DOAS total ozone column amounts against ground-based measurements at an African equatorial belt
Abstract:
The total ozone column amount (TOCA) values from the Ozone Monitoring Instrument (OMI) derived from OMI/Aura ozone (O3) differential optical absorption spectroscopy (DOAS) V003 (OMDOAO3) have been validated against the ground-based TOCA values derived from Dobson and the Norwegian Institute for Air Research UV measurements in Kampala (0.31º N, 32.58º E, 1200 m), Uganda, for the period between 2005 and 2018. Under all-sky conditions, the OMI retrieval algorithm was found to underestimate the TOCA values with mean bias (MnB), root mean square error (RMSE), and correlation coefficient (r) values ranging from about -3.4% to -1.7%, 2.4% to 4.9%, and 0.73 to 0.90, respectively. When only days with a radiation modification factor greater than or equal to 65% were considered, the MnB, RMSE, and r values between TOCA values derived from ground-based and OMI measurements improved, and they ranged from -2.5% to -1.3%, 1.4% to 3.8%, and 0.8 to 0.91, respectively. A good agreement was found between TOCA values derived from Dobson measurements and those derived from OMI satellite measurements with MnB, RMSE, and r values of about -1.8%, 1.4%, and 0.91, respectively. This was due to the fact that Dobson measurements were taken only when the sky was perceived clear. The underestimation of TOCA values by the OMI retrieval algorithm was found to be due mainly to clouds and aerosols.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Measurement of Air Content in Concrete
The pressure method,...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...

