Reliability of computed tomography-based renal cortex volume to determine split renal function in preoperative living
Chuthaporn Surawech1, Kewalee Sasiwimonphan1
1Department of Radiology, Division of Diagnostic Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
Objective:
The purpose of this study was to assess the utility of CT-based renal cortex volume to estimate split renal function (SRF) in pre-transplant living kidney donors and to evaluate its reliability to predict graft function in the recipients.
Methods:
Our study recruited all adult potential donors who had both Tc-99m-diethylenetriamine pentacetate (DTPA) scintigraphy and CT angiography of the abdominal aorta done before donating their kidney. We compared the correlation between CT-based renal cortex volume combined with kidney function and DTPA scan as well as post-donation kidney function in the recipients.
Results:
The correlation between CT-based split cortex volume and DTPA-measured SRF before transplantation was strong (intraclass correlation coefficient = 0.954-0.968). The inter-rater reliability of two radiologists also showed substantial agreement (intraclass correlation coefficient = 0.97, p < 0.001). In contrast, the correlations between renal cortical volume of donated kidney adjusted to recipient body weight and recipient kidney function was poor at both 2 week and 2 year follow-up.
Conclusion:
CT-based renal cortex volume combined with pre-operative kidney function appears to be precise and reproducible to evaluate pre-transplant SRF. Nevertheless, the prediction of recipient graft function needs to be further investigated to ensure a good outcome.
Advances In Knowledge:
This method is practicable for all potential donors who undergo kidney transplantation in terms of streamline donor workup without compromising information.
Related Concept Videos
Imaging Studies III: Computed Tomography
Kidney Transplant I: Introduction
Kidney Transplant II: Surgical Procedure
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Imaging Studies VII: Vascular Imaging